BOP Equipment
What should be the Rated Working Pressure of the BOP Stack as per API?
a. Maximum
anticipated MAASP
b. Maximum
anticipated Pore Pressure
c. Maximum
anticipated Surface Pressure
d. Maximum
anticipated Hydraulic Pressure
e. Maximum
anticipated Pressure Loss in the system
f. Maximum
anticipated Bottom Hole Pressure
Pressure
Testing
Cup Type Tester
Max pressure test?
•13
3/8” 68 # K55 Casing (ID 12.415”)
•OD
Mandrel CTT = 6.25”
•P/T
on csg.
with 5” 19.5 # DP?
Grade
E DP in use.
(Min
yield 395k lbs use
85% of maximum )
******************
Cup Type Tester
Max pressure test?
Max Pressure = Max Force / Area
Area =
p (ID2
– OD2) / 4
Area =
p (12.4152
– 52) / 4
=
101.4 square inch
Pressure = 395,000 x 0.85
101.4
Pressure = 3310 psi
****************************